Product Description

The Allen-Bradley/Rockwell Automation 2706-A41J is a high-quality industrial message display module from the Dataliner DL10 series, designed for custom panel or enclosure installation in environments with ambient temperatures between 0 and 50 degrees Celsius. It features NEMA Type 12/13 or 4 protection (4X for stainless steel faceplate versions), complies with European electromagnetic compatibility and low voltage standards (EN 50081-2/50082-2, EN 61131-2:1992/EN 60950:1992), and supports ASCII characters via RS-232 and RS-422 ports. The VFD display (365.7 x 157.4 mm) shows 4 lines of 20 characters each, visible from 73.1 meters. Operating at 120 Volts AC (50-60 Hertz) with a 55 Volt-Amp power consumption, and housed in a NEMA Type 12/13 enclosure, the 2706-A41J is commonly used in warehouses and factories for displaying messages and alarms, and often requires power-line filters in European Union applications to prevent power line interference.

Is Your Device Showing These Signs?

The Allen Bradley 2706-A41J HMI commonly experiences issues related to touchscreen unresponsiveness, display backlight failure, and communication errors on the serial or Ethernet ports. Memory corruption can occur, leading to program faults and data loss, necessitating firmware reflashing or memory module replacement. Power supply failures are also a frequent problem, resulting in complete unit inoperability. Resolve these issues through component-level repairs, firmware updates, and rigorous testing to ensure optimal HMI performance.

Technical specifications

  • The Allen-Bradley/Rockwell Automation Dataliner DL10 message display module, model number 2706-A41J, is intended for industrial message display with an operating temperature of 0 to 50 degrees Celsius (32 to 122 degrees Fahrenheit) and an enclosure rating of NEMA Type 12/13, 4 (indoor use), 4X (stainless steel faceplate versions), compliant with EN 50081-2/50082-2 (Electromagnetic Compatibility) and EN 61131-2:1992/EN 60950:1992 (Low Voltage), supporting ASCII characters through RS-232, RS-422 (parallel arrangement) communication ports, displaying in a 4 lines x 20 characters per line format using a VFD (Vacuum Fluorescent Display) with a display size of 365.7 x 157.4 millimeters (14.4 x 6.2 inches) and a viewing distance of 240 feet (73.1 meters), requiring an input power of 120 Volts AC at a line frequency of 50 to 60 Hertz with a power consumption of 55 Volt-Amps, typically used in warehouses and factories for message and alarm delivery, customizable and compatible with various hardware components, with power-line filters recommended for use in the European Union to prevent interference currents.

Our Repair Process for the

2706-A41J

Our repair process for the Allen Bradley 2706-A41J HMI begins with a comprehensive diagnostic evaluation to identify the root cause of the malfunction, addressing common issues such as touchscreen unresponsiveness, display backlight failure, serial or Ethernet communication errors, memory corruption, and power supply failures. Technicians perform component-level repairs, replacing faulty parts and conducting firmware reflashing or memory module replacements as required to resolve program faults and data loss. The HMI undergoes rigorous testing, including functional and performance assessments, to verify complete resolution of the identified issues and ensure optimal operational performance before it is returned.

Your Guarantee: Warranty & Lifetime Support

Your satisfaction is our top priority, and we confidently stand behind the quality of our repairs. That's why every repair service is covered by our comprehensive 24-month warranty. Furthermore, we offer lifetime phone support – if you have questions or need assistance related to our repair down the road, we're here to help. Our service commitment is straightforward: we guarantee our work, and if you're not satisfied, we will make it right. Learn More about our Repair process.

Comprehensive Repairs You Can Depend On

We take immense pride in the quality and reliability of our work. Our process goes beyond simply fixing the immediate problem. We perform a comprehensive inspection of your main board (or other equipment) and proactively replace components known to be failure-prone or showing signs of potential future failure. Before any item is returned, it undergoes rigorous functional testing to ensure it meets performance specifications and operates flawlessly. Visit our main Repair Services page to learn more.

Save Significantly

Our primary goal is to save you hundreds, or even thousands, of dollars compared to the cost of new equipment replacement. By repairing existing components, we provide an economical solution that is also eco-friendly. At Roc Industrial, our commitment to integrity and community drives our consistent growth and ensures you receive a reliable, cost-effective solution.

Please Note: Roc Industrial operates as an independent service provider and is not an authorized distributor for the manufacturers or brands mentioned. Consequently, the original manufacturer's warranty is not applicable to items repaired or sold by us. Roc Industrial provides its own 2-year warranty on all repair services performed.

bottom of page