Product Description
The Allen-Bradley 2711P-RN16 is a communication adapter for PanelView Plus, PanelView Plus CE, and PanelView Plus 6 graphic terminals (7-15 inch/700-1500 range). It installs on top of a Logic module to provide Data Highway Plus (DH+), Remote I/O (RIO), and DH-485 network connectivity. When used with PanelView Plus 6, only DH+ and DH-485 are supported. It is not compatible with PanelView Plus 7. The adapter features one DH485 port and one DH+/RIO port, both using phoenix connectors, and two LED status indicators for network diagnostics. DH+ and RIO support multi-node, long-distance communication via daisy-chain topology, requiring 1770-CD or Belden Blue Hose cable. DH-485 also supports daisy-chain topology, using Belden #3106A or #9842 cable. The 2711P-RN16 enables remote programming and monitoring, process and device status monitoring, data acquisition, and supervisory controls. Excessive DH-485 traffic can impact performance. The DH-485 network supports initiators and responders, with a default maximum node address of 31. At least one initiator is required. The maximum network length is 4000 feet, supporting up to 32 devices, with the ability to add/remove nodes without network disruption. Shipping weight is 3 pounds, and dimensions are 11 x 8 x 6 inches.
Is Your Device Showing These Signs?
The Allen Bradley 2711P-RN6 commonly experiences communication failures stemming from corrupted firmware, necessitating a firmware upgrade or re-flash. Ethernet port damage due to electrostatic discharge or voltage surges requires port replacement or complete unit repair. Dim or non-functional backlights are resolved through backlight inverter or LCD replacement. Touchscreen unresponsiveness is corrected via touchscreen calibration or replacement. Power supply failures, indicated by a lack of power or intermittent operation, demand power supply repair or replacement.
Technical specifications
The Allen-Bradley 2711P-RN6 is a communication adapter for PanelView Plus (7-inch to 15-inch, 700 to 1500 series), PanelView Plus CE (7-inch to 15-inch, 700 to 1500 series), and PanelView Plus 6 (7-inch to 15-inch, 700 to 1500 series) graphic operator terminals, incompatible with PanelView Plus 7, supporting Data Highway Plus (DH+), Remote I/O (RIO), and DH-485 networks (DH+ and DH485 only for PanelView Plus 6, no RIO support). It features one DH485 port (6-pin Phoenix connector) and one DH+ / RIO communication port (3-pin Phoenix connector), with two LED status indicators (OFF: Channel is not online; Blinking Green: Device is the only node on the network; Solid Green: Device is online and receiving token; Blinking Red: DH-485: Duplicate node / DH+: Parity error; Solid Red: Failed self-test). It supports daisy-chain topology for DH+, RIO, and DH-485, requiring 1770-CD or Belden Blue Hose cable for DH+ / RIO and Belden #3106A or #9842 for DH-485, offering multi-node communication, long-distance support, and fast data transmission rate for DH+ / RIO, and remote programming and monitoring support for DH-485. Functionality includes process status monitoring, device status monitoring, data acquisition and monitoring, program uploading and downloading, and supervisory controls, with a maximum network length of 4000 feet, up to 32 devices, node management supporting adding and removing nodes without disrupting the network, DH-485 device classes of initiators and responders, a maximum configurable node address of 31 (default) for all initiators and responders, requiring at least 1 initiator on the DH-485 network, with a shipping weight of 3 pounds and shipping dimensions of 11 x 8 x 6 inches.
Our Repair Process for the
2711P-RN6
Our repair process for the Allen Bradley 2711P-RN6 begins with a comprehensive diagnostic evaluation to pinpoint the failure. Communication failures due to corrupted firmware are addressed through a mandatory firmware upgrade or re-flash. Ethernet port damage is rectified by port replacement or complete unit repair. Dim or non-functional backlights necessitate backlight inverter or LCD replacement. Touchscreen unresponsiveness is corrected through touchscreen calibration or replacement. Power supply failures require power supply repair or replacement to restore proper operation.
Your Guarantee: Warranty & Lifetime Support
Your satisfaction is our top priority, and we confidently stand behind the quality of our repairs. That's why every repair service is covered by our comprehensive 24-month warranty. Furthermore, we offer lifetime phone support – if you have questions or need assistance related to our repair down the road, we're here to help. Our service commitment is straightforward: we guarantee our work, and if you're not satisfied, we will make it right. Learn More about our Repair process.
Comprehensive Repairs You Can Depend On
We take immense pride in the quality and reliability of our work. Our process goes beyond simply fixing the immediate problem. We perform a comprehensive inspection of your main board (or other equipment) and proactively replace components known to be failure-prone or showing signs of potential future failure. Before any item is returned, it undergoes rigorous functional testing to ensure it meets performance specifications and operates flawlessly. Visit our main Repair Services page to learn more.
Save Significantly
Our primary goal is to save you hundreds, or even thousands, of dollars compared to the cost of new equipment replacement. By repairing existing components, we provide an economical solution that is also eco-friendly. At Roc Industrial, our commitment to integrity and community drives our consistent growth and ensures you receive a reliable, cost-effective solution.

Please Note: Roc Industrial operates as an independent service provider and is not an authorized distributor for the manufacturers or brands mentioned. Consequently, the original manufacturer's warranty is not applicable to items repaired or sold by us. Roc Industrial provides its own 2-year warranty on all repair services performed.