Product Description
The Allen-Bradley 2711P-RP3 logic module, part of the PanelView Plus 700-1500 series, features 256 MB of flash memory and RAM, DC input, a Compact Flash card slot, Ethernet, Serial, and two USB ports. It's incompatible with PanelView Plus 6 terminals. Upon reorganization or startup, the terminal enters configuration mode, automatically running the MER application. To monitor ambient temperature and battery voltage (minimum 275V AC, requiring replacement if lower) in PanelView Plus 700-1500 terminals, access the terminal information tab via pattern mode. For PanelView Plus CE terminals, use the hardware display regulator panel application. The 2711P-RP3 is user-friendly and requires no specialized knowledge, providing user protection against damage.
Is Your Device Showing These Signs?
The Allen Bradley 2711P-RP3 HMI module commonly experiences issues such as a failed backlight, resulting in a dim or unreadable display requiring backlight replacement. Touchscreen unresponsiveness or inaccurate calibration necessitates recalibration or touchscreen replacement. Communication errors over Ethernet or serial ports demand troubleshooting of network configurations, cable integrity, or port replacement. Corrupted firmware leads to operational faults, mandating firmware reflashing or memory module replacement. Power supply failures prevent the HMI from powering on, requiring power supply repair or replacement.
Technical specifications
The Allen-Bradley 2711P-RP3 Logic Module is part of the PanelView Plus 700 to 1500 series, featuring 256 MB of Flash Memory and 256 MB of RAM. It operates on DC input power and offers connectivity through a Compact Flash Card Slot, Ethernet Port, Serial Port, and two USB Ports. It is incompatible with Allen-Bradley PanelView Plus 6 terminals. Upon terminal reorganization or startup, it enters automatic configuration mode, and the MER application automatically runs. Display Temperature and Battery Voltage Monitoring are accessible via Pattern Mode > Terminal Settings > Structure Information > Terminal Information, with PanelView Plus CE Terminals utilizing a hardware display regulator panel application. A minimum Battery Voltage Requirement of 275 Volts AC is needed, with replacement required if lower. No special knowledge is required for operation.
Our Repair Process for the
2711P-RP3
Our repair process for the Allen Bradley 2711P-RP3 HMI module begins with a comprehensive diagnostic evaluation to pinpoint the failure. Backlight issues are resolved through direct backlight replacement, restoring screen visibility. Touchscreen problems undergo recalibration, and replacement occurs if unresponsiveness persists. Communication errors necessitate a thorough examination of network configurations and cable integrity, with port replacement executed as needed. Firmware corruption requires immediate reflashing or memory module replacement to restore proper operation. Power supply failures are addressed through repair or complete power supply replacement, ensuring the HMI powers on reliably.
Your Guarantee: Warranty & Lifetime Support
Your satisfaction is our top priority, and we confidently stand behind the quality of our repairs. That's why every repair service is covered by our comprehensive 24-month warranty. Furthermore, we offer lifetime phone support – if you have questions or need assistance related to our repair down the road, we're here to help. Our service commitment is straightforward: we guarantee our work, and if you're not satisfied, we will make it right. Learn More about our Repair process.
Comprehensive Repairs You Can Depend On
We take immense pride in the quality and reliability of our work. Our process goes beyond simply fixing the immediate problem. We perform a comprehensive inspection of your main board (or other equipment) and proactively replace components known to be failure-prone or showing signs of potential future failure. Before any item is returned, it undergoes rigorous functional testing to ensure it meets performance specifications and operates flawlessly. Visit our main Repair Services page to learn more.
Save Significantly
Our primary goal is to save you hundreds, or even thousands, of dollars compared to the cost of new equipment replacement. By repairing existing components, we provide an economical solution that is also eco-friendly. At Roc Industrial, our commitment to integrity and community drives our consistent growth and ensures you receive a reliable, cost-effective solution.


Please Note: Roc Industrial operates as an independent service provider and is not an authorized distributor for the manufacturers or brands mentioned. Consequently, the original manufacturer's warranty is not applicable to items repaired or sold by us. Roc Industrial provides its own 2-year warranty on all repair services performed.
Buying Options
To receive a quote within 2 hours, please provide us with the details of your requirements. Our team will promptly review your request and send you a custom offer.
Ships from Rochester, NY